AR15 repair

AR-15 Troubleshooting and Repair: Failure to Cycle

Common Causes of AR-15 Failure to Cycle and How to Troubleshoot and Repair Them

If you own an AR-15, you know that it can be a reliable and accurate rifle. But like any firearm, it can experience problems. One of the most common issues is failure to cycle. This can be caused by a variety of factors, but the good news is that it can usually be fixed with a few simple steps.

The first thing to do is to check the ammunition. Make sure that it is the correct caliber and that it is in good condition. If the ammo is old or damaged, it could be causing the failure to cycle.

Next, check the gas system. Make sure that the gas block is properly aligned and that the gas tube is not blocked. If the gas system is not functioning properly, it can cause the rifle to fail to cycle.

If the gas system is functioning properly, then the next step is to check the bolt carrier group. Make sure that the bolt is properly lubricated and that the extractor is not damaged. If the bolt carrier group is not functioning properly, it can cause the rifle to fail to cycle.

Finally, check the buffer and spring. Make sure that the buffer is properly seated and that the spring is not damaged. If the buffer and spring are not functioning properly, it can cause the rifle to fail to cycle.

If you have checked all of these components and the rifle still fails to cycle, then it may be time to take it to a gunsmith for further inspection. A gunsmith can diagnose the problem and make any necessary repairs.

In most cases, failure to cycle can be fixed with a few simple steps. However, if the problem persists, it is best to take the rifle to a gunsmith for further inspection. With a little bit of troubleshooting and repair, you can get your AR-15 back up and running in no time.

Step-by-Step Guide to Diagnosing and Fixing AR-15 Failure to Cycle Issues

If you’re having trouble getting your AR-15 to cycle properly, don’t worry – you’re not alone. Many AR-15 owners have experienced this issue at some point, and it’s usually a relatively easy fix. Here’s a step-by-step guide to diagnosing and fixing AR-15 failure to cycle issues.

Step 1: Check the Gas System

Ar15 Repair

The first step is to check the gas system. Make sure the gas block is properly aligned and that the gas tube is properly connected. If the gas block is misaligned, it can cause the gas to be blocked, which will prevent the gun from cycling properly.

Step 2: Check the Buffer and Spring

The next step is to check the buffer and spring. Make sure the buffer is properly seated in the buffer tube and that the spring is properly installed. If the buffer is not properly seated, it can cause the gun to not cycle properly.

Step 3: Check the Bolt Carrier Group

The next step is to check the bolt carrier group. Make sure the bolt is properly seated in the carrier and that the carrier is properly lubricated. If the bolt is not properly seated, it can cause the gun to not cycle properly.

Step 4: Check the Magazine

The next step is to check the magazine. Make sure the magazine is properly loaded and that the follower is properly seated. If the magazine is not properly loaded, it can cause the gun to not cycle properly.

Step 5: Check the Ammunition

The last step is to check the ammunition. Make sure the ammunition is properly loaded and that it is the correct caliber for your gun. If the ammunition is not properly loaded, it can cause the gun to not cycle properly.

Once you’ve gone through these steps, your AR-15 should be cycling properly. If it’s still not cycling properly, it may be time to take it to a gunsmith for further diagnosis and repair.

Leave a Reply